These totally exhaust system are designed for 100% exhaust of HEPA filtered air outside the room through a exhaust duct protects user product as well as the laboratory. Fitted with Touch Screen LCD Controller within built Data Logger and data transfer facility.
Features
- 100 % air exhaust
- Negative pressure air surrounding all biological contaminated parts
- Class II, Type B2 cabinets are total exhaust cabinets, widely used in toxicology laboratories and similar applications where chemical effluent is present and clean air is essential.
- There is no recirculation within the work area.
- Room air enters through a blower/motor in the top of the cabinet and passes through a HEPA supply filter into the work area as the vertical unidirectional airflow.
- Descending air is pulled through the base of the cabinet through the perforated front and rear grilles.
- Simultaneously, air entering through the perforated front opening is pulled through the grille and exhausted immediately,
- 100% of the air is pulled into the facility exhaust system for appropriate treatment.
- Type B2 cabinet is hard-connected to an exhaust system.
- Negative pressure surrounds the work area with double-wall plenums for protection.
- Air drawn through pre-filter is made to pass through highly effective HEPA (High-Efficiency Particular Air) filters. The prefilter fitted extends the life of the HEPA filter drastically. Fitted with HEPA Filter made from water-resistant, fire retardant, imported microfine glass fiber media; conforms to EU – 14 Grade, with an efficiency rating better than 99.999% for 0.3 μ. These filters are designed to accommodate higher air flow volume.
- Prefilter is made from Non-Woven Synthetic with HDPE mesh and Al expanded mesh on the air leaving side; conforms to EU-4 /G-4 Grade, with the efficiency of down to 10 microns. These filters can be cleaned by compressed air & also washable.
- Mounted on heavy tubular stand with lockable castors.
- Aerodynamic airflow grills maintain safety and prevents blockage.
- U.V and fluorescent interlock available
- Ergonomic and comfortable sloped front window for comfortable head and elbow rest position, thus reducing fatigue
- Sash is counterbalanced for smooth and lightweight operation with a standard opening for easier access to the work zone and enhanced user safety.
- CLASS-II design ensures PERSONNEL, PRODUCT and ENVIRONMENT PROTECTION.
Cass II Biosafety Cabinet Protection
- Personnel protection from harmful agents used inside the biosafety cabinet.
- Product protection to avoid contamination of the works, experiment or process from outside contaminants.
- Environmental protection from contaminants contained within the biosafety cabinet.
Cass II Biosafety Cabinet Key Features
- A front access opening with carefully maintained inward airflow.
- HEPA-filtered, vertical, unidirectional airflow within the work area.
- HEPA-filtered exhaust air to the room or exhaust to a facility exhaust system.
Cass II Biosafety Key Applications
- Typically used for biosafety levels 1 through 3 for low to moderate risk biological agents.
- The type B2 total exhaust cabinets are widely used in toxicology laboratories and similar applications where chemical effluent is present and clean air is essential.
- All types of Class II cabinets may be used in biosafety level 4 laboratories when workers utilize positive pressure suits. However, for level 4 Class III cabinets are recommended.
Upper & Front Cover
Removable upper and front cover simplifies filter, blower and front control panel replacements and maintenance easier.
Material Of Construction
Working Table is made up of Stainless Steel (SS-304). External Cabinet is fabricated of electrogalvanized powder coated OR Stainless Steel (SS-304) (as ordered).
Front Window/Sash
Front Sash consists of a thick plexi-glass or toughened transparent glass for a clear inside view. In addition it serves optimum resistance and protection from harmful UV rays, protection user from exposure to harmful Ultraviolet radiation.
Drain Trough With Valve
The trough at base is easy to clean and for offloading liquid spillage if any.
Decontamination By UV Lamp
UV Lamp to produce UV rays of 253.7 nanometers and fluorescent lamp are interlocked and the motor blower is turned off/on as and when the front sash is closed/opened. UV lamps function through a timer (Option) to control the decontamination cycle and maximize UV lamp life. The UV lamp shuts off once the desired set time of decontamination is over and switches the fluorescent lamp to ON position.
Splash Proof Electric Supply Socket
Splash proof sockets is provided for optimum convenience of using small electrical devices inside the cabinet.
Front Airflow Intake Grid
Aerodynamically designed front airflow intake grid eliminates potential turbulence and contamination.
Floor Stand And Castor Wheels
Floor Stand is made up of heavy-duty tubular pipe duly powder coated and fitted with durable castor wheels for rotation and total brake system on front wheels.
Controller
- All system and control through a 3.5” feather touch LCD display with in-built data logging (real-time).
- Audiovisual alarm for blower tripping and fault acknowledgment.
- Alarm triggers in case front door is raised more than 8” (i.e. safe clear opening during operation)
- U. V. Light with Hour Meter & interlocking arrangement to put off U. V. light if either side door opens
- UV Light with Hour Meter
- Alarm for the front door of BSC for safe clear opening
Technical Specifications & Ordering Informations | ||||
Model (Cabinet: CRC) | LXMBSCD-2 (B2-CRC) | LXMBSCD-3 (B2-CRC) | LXMBSCD-4 (B2-CRC) | LXMBSCD-6 (B2-CRC) |
Model (Cabinet: SS) | LXMBSCD-2(B2-SS) | LXMBSCD-3(B2-SS) | LXMBSCD-4 (B2-SS) | LXMBSCD-6 (B2-SS) |
Inner Dimensions (W*D*H) | 600*610*675mm | 900*610*675mm | 1200*610*675mm | 1780*610*675mm |
MOC | Worktop : Stainless steel (SS-304), Exterior Cabinet : Cold Rolled Steel Duly Powder Coated OR Stainless Steel (SS-304) (as ordered) | |||
Controller | ALL SYSTEM AND CONTROL THROUGH A 3.5” Feather Touch LCD DISPLAY WITH IN-BUILT DATA LOGGING (REAL TIME)..Alarm triggers in case front door is raised more than 8” (i.e. safe clear opening during operation)U. V. Light with Hour Meter & interlocking arrangement to put off U. V. light if either side door opensUV Light with Hour MeterAlarm for the front door of BSC for safe clear opening | |||
Minipleat HEPA Filter | Mounted on aluminum frame, of rating, Prefilter are made from Non-Woven Synthetic with HDPE mesh and Al expanded mesh on air leaving side; conforms to EU -4 /G-4 Grade, with the efficiency of down to 10 microns. These filters can be cleaned by compressed air & also washable. | |||
Pre Filter | Mounted on an aluminum frame, of rating, Prefilter are made from Non-Woven Synthetic with HDPE mesh and Al expanded mesh on air leaving side; conforms to EU-4 /G-4 Grade, with the efficiency of down to 10 microns. These filters can be cleaned by compressed air & also washable. | |||
Exhaust Filter | Air drawn through pre-filter is made to pass through highly effective HEPA (High-Efficiency Particular Air) filters. The prefilter fitted extends the life of the HEPA filter drastically. Fitted with HEPA Filter made from water-resistant, fire retardant, imported microfine glass fiber media; conforms to EU – 14 Grade, with an efficiency rating better than 99.999% for 0.3 μ. These filters are designed to accommodate higher air flow volume. | |||
Supply/Main Filter | Air drawn through pre-filter is made to pass through highly effective HEPA (High-Efficiency Particular Air) filters. The prefilter fitted extends the life of the HEPA filter drastically. Fitted with HEPA Filter made from water-resistant, fire retardant, imported microfine glass fiber media; conforms to EU – 14 Grade, with an efficiency rating better than 99.999% for 0.3 μ. These filters are designed to accommodate higher air flow volume. | |||
Sash Lift | Can be lifted and adjusted manually | |||
Heavy Duty Exhause System | Standard fitted to the system for 100% exhaust | |||
Electrical Socket | Electrical Socket is provided for using small electrical devices | |||
Power Supply | 220/230 Volts AC supply |
Options
- Magnehelic Pressure Differential Gauge (To track filter pressure in lieu of static pressure manometer).
- Electronic filter choke alarm (Differential Pressure Monitor).
- Exhaust ducting per running feet.
- Gas Burner.
- Virus Burn Out.
- Spare U.V. Germicidal Tube (1.5 feet).
- Spare U.V. Germicidal Tube (3.0 feet).