Integrated Water Treatment Setup on Laboratory Scale:

  • Treatment process wise list of various Components used :         
  1. Reservior Tank for storage of Raw water from Industries.
  2. EC Tank
  3. Settling Tank
  4. Gravity Filtration
  5. Bioadsober
  6. Membrane Filtration Process
  7. Final clean water storage tank.
  8. Pipeline Fittings.
  9. Pumps used in various steps.
  10. Chillers and Heaters
  11. Central control pannel to montrate the entire process.
  12. Accessories required for this process.

Waste Water Treatment Setup :

  • Treatment process wise list of various Components used :         
  1. SS Reservior Tank for storage of Raw water from Industries, total capacity of about 1500lit. each and working volume will be more or less 1200lit.
  2. SS Impellers( Ruston Turbine type), fitted from the top driven technology with the help of industrial motor and gear assembly. RPM of these motro are digitally controlled from the central control pannel.
  3. Inlet and out let purpose various types of pipes are fitted in this unit.
  4. Numbers of peristaltic pumps and other pumps are fitted as desired for the process.
  5. Final clean water storage tank.
  6. Pipeline Fittings.
  7. Pumps used in various steps.
  8. Chillers and Heaters
  9. Central control pannel to montrate the entire process.
  10. Accessories like filters, baffle etc. required for this process.

Bio-reactor apparatus, consisting of the following items :-

  1. Reaction vessel  :-
    1. Quantity                                          2 No.
    1. MOC                                                 SS304/resign quoted PVC sheet
    1. Capacity                                          5 litres (approx.)
    1. Pressure rating                              Upto 4 kg/cm2(g)
    1. Temperature rating                      Upto 125 OC
    1. Pressure gauge                              Provided
    1. Safety valve                                     Provided
  • Settling  washing & Filtering columns :-
    • Quantity                                          2 Nos.
    • MOC                                                 SS304
    • Capacity                                          2 litres each (approx.)
    • Mixing arrangement                    Recirculation type mixing arrangement provided
    • Settling arrangement                   Bottom outlet cock provided for layer separation
  • Piping :-
    •  One set of interconnecting piping of SS 304, with valves & fittings as required
  •  
    • One set of magnatic noncontact pump with flowmeters  & fittings as required.
  • Mounting :-
    • MS structure for free standing floor mounting arrangement