Recirculates 70% of HEPA filtered air and rest 30% air exhausted through optional exhaust system. Fitted with Microprocessor LCD display controller with facility to display air velocity across work table.

Features

  • 30% air exhaust
  • 70% air recirculation
  • HEPA OR MINIPLATE -filtered exhaust air in Type A2 cabinet may be recirculated into the room or exhausted to the outdoors through a canopy exhaust connection.
  • HEPA OR MINIPLATE -filtered downflow air is a portion of mixed downflow and inflow air from a common plenum.
  • Negative Pressure air surrounding all biological contaminated ducts and plenums.
  • Negative pressure surrounds the work area with double wall plenums for protection.
  • Air drawn through pre-filter is made to pass through highly effective HEPA OR MINIPLATE (High Efficiency Particular Air) filters. The prefilter fitted extends the life of HEPA OR MINIPLATE filter drastically. Fitted with HEPA OR MINIPLATE Filter made from water resistant, fire retardant, imported micro fine glass fibre media; conforms to EU – 14 Grade, with an efficiency rating better than 99.999% for 0.3 μ.These filters are designed to accommodate higher air flow volume.
  • Prefilter are made from Non-Woven Synthetic with HDPE mesh and Al expanded mesh on air leaving side; conforms to EU – 4 / G-4 Grade, with an efficiency of down to 10 micron. These filters can be cleaned by compressed air & also washable.
  • Mounted on heavy tubular stand with lockable castors.
  • Aerodynamic airflow grills maintain safety and prevent blockage
  • U.V and fluorescent interlock available
  • Ergonomic and comfortable 10 degrees sloped front window for comfortable head and elbow rest position, thus reducing fatigue.
  • The sash is counterbalanced for smooth and lightweight operation with the standard opening of 200mm ±10 mm for easier access to work zone and enhanced user safety.

Cass II Biosafety Cabinet Protection

  • High velocity air forced through HEPA OR MINIPLATEfilters.
  • Filtered air is thrown in the chamber through jet nozzles with a high velocity which in turn disperse particulate matter on all surface.
  • The lower portion of the Air showers suck the contaminated air and allow it to pass to blower supply plenum through pre-filter installed at the base.
  • This process is a continuous process in which air is continuously filtered and recirculated inside the chamber without any exchange with the external environment.

Upper & Front Cover

Removable upper and front cover simplifies filter, blower and front control panel replacements and maintenance easier.

Material Of Construction

Working Table is made up of Stainless Steel (SS-304). External Cabinet is fabricated of CRC sheet duly powder coated OR Stainless Steel (SS-304) (as ordered).

Front Window/Sash

Front Sash consists of a toughened transparent glass/ thick PP sheet for a clear inside view. In addition, it serves optimum resistance and protection from harmful UV rays, protects user from exposure to harmful Ultraviolet radiation.

Drain Trough With Valve

The trough at base is easy to clean and for offloading liquid spillage if any.

Decontamination By UV Lamp

UV Lamp to produce UV rays of 253.7 nanometer and fluorescent lamp are interlocked and motor blower are turned off/on as and when front sash is closed/opened. UV lamps functions through a timer (Option) to control the decontamination cycle and maximize UV lamp life. The UV lamp shuts off once the desired set time of decontamination is over and switches the fluorescent lamp to ON position.

Splash Proof Electric Supply Socket

Splash proof sockets is provided for optimum convenience of using small electrical devices inside the cabinet.

Front Airflow Intake Grid

Aerodynamically designed front airflow intake grid eliminates potential turbulence and contamination.

Floor Stand and Castor Wheels

Floor Stand is made up of heavy-duty tubular pipe duly powder coated and fitted with Buffer with labeller or durable castor wheels for rotation and total brake system on front wheels.

Controller

These models are provided with both anlage and  Microprocessor Based Digital Controller with LCD display and air velocity sensor to display the air velocity across the work table or only conventional on/off type switches as ordered.

Technical Specifications & Ordering Information
Model (Cabinet: CRC)LXMBSCD-2  (A2-CRC)LXMBSCD-3 (A2-CRC)LXMBSCD-4 (A2-CRC)LXMBSCD-6 (A2-CRC)
Model (Cabinet: SS)LXMBSCD-2 (A2-SS)LXMBSCD-3 (A2-SS)LXMBSCD-4 (A2-SS)LXMBSCD-6 (A2-SS)
Inner Dimensions (W*D*H)600*610*675mm900*610*675mm1200*610*675mm1780*610*675mm
MOCWorktop : Stainless steel (SS-304), Exterior Cabinet : Cold Rolled Steel Duly Powder Coated OR Stainless Steel (SS-304) (as ordered)
Pre FilterMounted on frame, of rating, Prefilter are made from Non-Woven Synthetic with HDPE mesh and Al expanded mesh on air leaving side; conforms to EU-4 /G-4 Grade, with efficiency of down to 10 micron. These filters can be cleaned by compressed air & also washable.
Ehaust FilterAir drawn through pre-filter is made to pass through highly effective HEPA OR MINIPLATE  (High Efficiency Particular Air) filters. The prefilter fitted extends the life of HEPA OR MINIPLATE  filter drastically. Fitted with HEPA OR MINIPLATE  Filter made from water resistant, fire retardant, imported micro fine glass fibre media; conforms to EU – 14 Grade, with an efficiency rating better than 99.999% for 0.3 μ. These filters are designed to accommodate higher airflow volume.
Supply/Main FilterAir drawn through pre-filter is made to pass through highly effective HEPA OR MINIPLATE  (High Efficiency Particular Air) filters. The prefilter fitted extends the life of HEPA OR MINIPLATE  filter drastically. Fitted with HEPA OR MINIPLATE  Filter made from water resistant, fire retardant, imported micro fine glass fibre media; conforms to EU – 14 Grade, with an efficiency rating better than 99.999% for 0.3 μ. These filters are designed to accommodate higher airflow volume.
Sash LiftCan be lifted and adjusted manually
Power Supply220V/50Hz

Options

  • Magnehelic Pressure Differential Gauge (To track filter pressure in lieu of static pressure manometer).
  • Electronic filter choke alarm (Differential Pressure Monitor).
  • TFT Touch Screen Display Controller with air velocity sensor.
  • Exhaust ducting per running feet.
  • Gas Burner.
  • Virus Burn Out.
  • Spare U.V. Germicidal Tube (1.5 feet).

Spare U.V. Germicidal Tube (3.0 feet).